Chat with us, powered by LiveChat
arrow_back_ios

Main Menu

See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

Loudspeaker Testing

Loudspeakers and entertainment systems can be found just about everywhere: phones, cars, TVs, headphones, computers, toys, public announcement systems, and cinemas.

The end user has strong and clear ideas of the performance expected from a product, so it is crucial to transform these expectations into products that satisfy customers. Sound quality measurements help to ensure that customer preferences are met and provide a way to differentiate the product. However, sound quality is not the only parameter a manufacturer may want or need to evaluate:

 

  • Target setting – Are response, distortion, impedance, sensitivity, directivity, and other values where they need to be?
  • Acoustic material – How do lighter, more durable and less expensive materials affect the sound?
  • Structure – How does a change in cabinet or component design affect the vibrational and acoustic properties of a speaker?
  • Production – Can a manufacturer rely on pass/fail results and receive a quality product?

The number of tests involved in the verification of performance specifications and requirements can be overwhelming for an R&D engineer with a deadline and budget to meet. That is why in the industry, standardization, automation, data correlation and ease of use are such hot topics in R&D testing. Providing these features without compromising reliability and precision, means engineers can meet their targets quickly and efficiently.

System suggestion

loudspeaker testing

For loudspeaker testing we recommend PULSE Loudspeaker Test Application BZ-5603. This software supports measurements on loudspeakers, using an instrumentation set-up that includes a turntable to automatically record the directional characteristics of the test object. This application automates measurements of frequency response, harmonic distortion, directional response and calculation of Thiele-Small parameters using the simple impedance, added volume, added mass or laser methods. 

TYPE 4971-H-041

1/2" CCLD Pressure Field Microphone Set with BNC Connector

CCLD Pressure-field microphone for coupler, random-incidence and free-field measurements with 90° incidence and a frequency range of 5 Hz to 20 kHz

Type 4191

½-inch Free-field Microphone, Externally Polarized, 3.15 Hz – 40 kHz

Free-field microphone for high-precision, free-field measurements with a wide frequency range/bandwidth of 3.15 Hz to 40 kHz.

TYPE 3160

Generator Module

Designed for applications where system excitation is required, such as audio and electro-acoustic test applications.

TYPE 4930

Artificial Mastoid

Artificial Mastoid designed for the calibration of bone-conduction hearing aids by simulating the mechanical impedance of the human mastoid.

Type 2735

Measurement Power Amplifier

A compact, highperformance, 2 × 35 W power amplifier designed for electroacoustic and general-purpose applications.

TYPE 9640

Turntable system

Designed to rotate a test object, such as a loudspeaker, microphone, or hydrophone, for measurement of directional response.

BZ-5602, BZ-5603, BZ-5743 and BZ-5744

Automated test procedures for electroacoustic devices

Dedicated PULSE testing software applications for specific products including microphones, speakers and headsets.