See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

Weather conditions affect the propagation of sound, so wind speed and direction must be taken into account when measuring noise outdoors. Consequently, most standards for the measurement of environmental noise define limits for wind speed and direction.

Connect your MM-0316-A or MM-0256-A weather station kit to your Type 2250, 2270 or 2250-Light sound level meter and turn it on. , There’s no need for separate batteries to power the weather station. Select the necessary weather parameters in the setup menu and you’re ready to start measuring.

USE SCENARIOS

  • Log wind speed and calculate ave., max. and min. values
  • Log wind direction and calculate ave., max. and min. values
  • Measurement of precipitation (rainfall), atmospheric pressure, temperature and relative humidity*

Since the wind sensors are based on ultrasound technology, they have no moving parts and operate well above the upper frequency limit of the microphone, allowing placement close to the measurement position.

The ultrasonic wind sensor starts measuring at 0 m/s – in contrast to traditional “cup type” wind meters that struggle at low wind speeds. With no moving parts, its performance doesn't degrade over time.

The kits are lightweight, and the durable carrying case keeps your weather station safe during transport and while in storage.
The free version of Measurement Partner Suite allows you to view your results. To gain the full benefit from this integrated solution, identify the portions of your logging profile where wind speed and direction are within the allowed limits using the report and marker wizard (BZ-5503-A-012).

Software

  • Integrated solution in version 4 and later of instrument software for sound level meters
  • Post-processing functionality with Measurement Partner Suite logging module BZ-5503-A-012