See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

Calibration of Sound Level Meters

Sound Level Meters are calibrated to the requirements in the standards they are designed to: IEC 61672, IEC 60651/ 60804, BS 7580, ANSI S1 4, and/or ANSI S1.43.

In addition to standard Sound Level Meter calibrations, HBK has approved service centers for calibration to meet national, legal requirements.

Also, 1/1-octave and 1/3-octave filter calibrations according to IEC 61260 are available for the frequency range from 6.3 Hz to 20 kHz.

For sound level meters, Brüel & Kjær provides two primary calibration services: accredited calibration and traceable calibration. These services include verification for selected countries and instrument verification.

Long-term Quality Assurance of Measurement Results

Professional Sound Level Meter calibration is a prerequisite for assuring the quality of your measurement results in the long term. Moreover, torque sensor calibration is an integral part of your ISO9001 certification.

Accredited calibration

Accredited calibration primarily fulfills requirements for legal purposes. Brüel & Kjær can provide the following accreditation for our sound level meters:

  • DANAK (English certificate)
  • A2LA (English certificate)
  • ENAC (Spanish certificate)
  • NATA (English certificate)
  • Inmetro, Brazil (Portuguese certificate)
Initial calibration

We recommend you order accredited calibration together with your new sound level meter, to start your calibration history from the very first day.

Re-calibration and measurement

Brüel & Kjær recommends annual re-calibration to provide data for an unbroken calibration history. This can then be used as a reference for internal requirements, for auditing required by authorities, or at the request of your customers.

Measurements of sound level meters are according to standards IEC 61672, IEC 60651/ 60804, BS 7580, ANSI S1 4, and ANSI S1.43. Initial calibrations on new sound level meters Types 2250, 2250 Light and 2270 will be performed according to IEC 61672. This applies for calibration according to accreditation bodies DANAK and ENAC.

Re-calibration of Types 2250, 2250 Light and 2270 for DANAK and ENAC will be performed to the latest standard, IEC 61672, unless you specify another standard on the order.

Measurements are traceable to institutions such as DPLA, NIST, NPL and PTB.

Additional Calibration
  • Calibration of filter response for 1/1-octave and 1/3-octave filters according to IEC 61260
  • Calibration of filters for the range 6.3 Hz to 20 kHz
  • Filter calibration is provided for an additional fee

Calibration Certificate

The certificate for accredited calibration gives you:

  • Proof that calibration has been performed according to the quality requirements in ISO 17025
  • Measurement results as well as associated uncertainties
  • Internationally accepted certificate with the logo of the accreditation body
  • Air temperature, air pressure and relative humidity

Traceable calibration

Measurements of sound level meters are performed according to standards IEC 61672, IEC 60651/ 60804, BS 7580, ANSI S1 4, and ANSI S1.43.

Initial calibrations on new sound level meters Types 2250, 2250 Light and 2270 are performed according to IEC 61672. This applies for calibration according to accreditation bodies DANAK and ENAC.

Re-calibration of Types 2250, 2250 Light and 2270 for DANAK and ENAC will be performed to the latest standard, IEC 61672, unless you specify another standard on the order.

Measurements are traceable to institutions such as DPLA, NIST, NPL and PTB.

Calibration Certificate

The certificate includes all measurement results.

Legal Verification

Brüel & Kjær can provide legal verification for:

  • Customers in Spain: Primitiva
  • Customers in Austria: Eichung

Please note that legal verification does not contain measurement results.

Verification - Conformance Testing

Brüel & Kjær can provide instrument verification:

  • A conformance test certifies that the instrument has been tested, has passed all production tests, and complies with the manufacturer's published specifications
  • You will receive a Certificate of Conformance

Please note that instrument verification does not contain measurement results.