See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

High Strain (LD20)

The LD20 is suitable for applications where high strain is to be expected

img

High Strain (LD20)

expand_more
chevron_left
chevron_right

LD20: Strain Gauge for High Strain or Compression up to 10 %

The use of the strain gauge LD20 is recommended wherever an extremely high strain or compression can occur (>5 %). The LD20 has a maximum elongation of +/- 100,000 µm/m (+/-10 %) and is attached with 30 mm leads.

Note: When the strain gauge is used to measure strains between +/- 50,000 µm/m - 100,000 µm/m, the fatigue strength is reduced compared to conventional Y series strain gauges.

Maximum Elongation

  • Maximum elongation of +/- 100,000 µm/m (+/-10 %).

Well suited for high strain rate measurements

Easy to Install

  • Simple installation process and easy handling 

Extremely flexible, as the Y Series universal strain gauges

Filter

close
LD20 - Data Sheet Data Sheets English

Certificates and Approvals

Strain Gauges and Accessories - Statement of Compliance Declaration of Conformity English
High Strain (LD20)
Type/technology Foil strain gauge
Application Stress Analysis / structural testing
Geometry Linear
Measuring grid length 10 mm, 6 mm
Measuring grid length 0.394 in, 0.236 in
Measuring grid width 4.6 mm, 5 mm, 2.8 mm
Measuring grid width 0.181 in, 0.197 in, 0.11 in
Carrier length 18.5 mm, 13 mm
Carrier length 0.728 in, 0.512 in
Carrier width 9.5 mm, 6 mm
Carrier width 0.374 in, 0.236 in
Temperature range Standard (up to 200°C)
Nominal resistance 120 Ohms, 350 Ohms
Gauge factor (measuring grid material) Constantan (ca 2.0)
Temperature response No matching of temperature response
Maximum elongation Enhanced
Fatigue life Standard
Connection configuration Leads
Mounting Glued
Grid protection Covered

List of accessories available for all variants of this family

Product Code Description
Cyanoacrylate adhesive (CA80) - 10 mL 1-CA80 Cyanoacrylate adhesive (CA80) - 10 mL
Measurement cable by the meter K-KAB-ML Measurement cable by the meter