See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

Type 1704-A-002

2-CHANNEL CCLD SIGNAL CONDITIONER

Type 1704-A-002 CCLD Signal Conditioner designed with built-in battery recharger, enabling in-situ conditioning for your measurements in the field and the lab.

img

Type 1704-A-002

expand_more
chevron_left
chevron_right

The Type 1704-A range of conditioners provides CCLD (Constant Current Line Drive) power for CCLD transducers such as microphones, accelerometers, and tachometer probes.

The 2-Channel Signal Conditioner includes features like a built-in, rechargeable battery optimised for in situ measurements. 

USE SCENARIOS

  • Provides power for microphones, accelerometers and other CCLD-compatible transducers
  • Industry standard CCLD power is compatible with wide range of DeltaTron® and ICP® sensors
  • Built-in Li-Ion battery and charger – ready to measure when you are
  • Powered and charged from PC's USB connector (with optional cable): no need for an extra mains adaptor
  • Wide range of gains (×1, ×10 and ×100) amplify signal before A/D to improve noise floor
  • Selectable acoustic bandpass and A-weighting (type 0) filters remove unwanted frequencies
  • Switches to quickly change settings and LEDs for fast verification of configuration
  • Both 2 × BNC and 3.5 mm stereo output connectors provide options to connect to A/D converters or sound cards

CCLD conditioning has advantages because it allows the transducer power to be delivered using the same coaxial cable that the transducer uses to return the measurement signal. This reduces cabling costs and improves noise immunity compared to multi-conductor cables.

Type 1704-A-002 signal conditioner has it's connectors, switches and status LEDs located on the front of the unit. A quick glance at the front of Type 1704-A confirms status and settings when making measurements in the field.

FLEXIBLE POWERING

The conditioner uses a Micro-B USB connector for power and charging the built-in rechargeable battery. Power comes from either the provided mains adaptor or from a powered USB port of a computer using the optional USB cable.

The built-in rechargeable battery is not only more convenient than replacing non-rechargeable batteries but also makes for a lower cost of ownership.

The rechargeable battery has at least 500 cycles, each lasting for 15 hours (Type 1704-A-001) or 13 hours (Type 1704-A-002)

GAIN AND FILTERING

The CCLD Signal Conditioner includes analogue gain and filtering.

Available gains settings include ×1 (0 dB), ×10 (+20 dB) and ×100 (+40 dB). Adding gain before the analogue to digital conversion can improve the system’s noise floor.

Likewise, the selectable acoustic band-pass filter can remove unwanted frequencies before the analogue to digital conversion. An A-weighting type 0 filter is also selectable.

Filter

close
Type 1704-A-002
Number of inputs 2, 1
Input IEPE / CCLD
Output Voltage (+/- 10V)
Interface None
Accuracy class ---
Degree of protection IP20
Housing Standalone
Real-time capabilities None