See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

Scout55

Mobile Carrier Frequency Amplifier: Ideal for Servicing Tasks

The SCOUT55 mobile carrier-frequency amplifier is optimally suited to be used for the purpose of on-site servicing, mainly due to its robust transport housing and easy-to-read display.

img

Scout55

expand_more
chevron_left
chevron_right

SCOUT55 Carrier Frequency Amplifier: Compact and Easy-to-Handle

The SCOUT55 mobile carrier frequency amplifier is suited for use in a wide range of servicing and calibration tasks in the test shop. The dust-protected housing not only makes the amplifier easy to transport, but it also features a carrying handle that can, additionally, serve as a stand. SCOUT55 processes the signals of force, pressure, displacement, and torque transducers as well as load cells based on various technologies.

SCOUT55 has a parameter memory for storage of up to eight data sets (formulations), two peak-value memories, and four limit value switches. The output of the measured data can be accessed through the freely scalable analog output, the RS232 serial interface, and the optional RS485 interface. Its easy-to-read, red LED display and robust membrane keypad make the SCOUT55 the ideal measuring amplifier for mobile use in industrial environments.

  • Accuracy class: 0.1
  • Interfaces: RS232; optionally RS485
  • Degree of protection: IP51 (front)

Optimum Results

  • 4.8 kHz carrier frequency amplifier for strain gauges in half- and full-bridge configurations, inductive half and full-bridges, LVDT, as well as piezoresistive and potentiometric transducers
  • Accurate measurement attributed to the 0.1 accuracy class
  • Large bandwidth of up to 1 kHz
  • High signal quality resulting from the use of carrier-frequency technology
  • High electromagnetic compatibility

Accurate measurement results due to carrier-frequency technology and a good EMC stability

Great Versatility

  • Integrated parameter memory for up to eight parameter sets (formulations)
  • Freely scalable analog output on the front (±10 V, ±20 mA, 4–20 mA)
  • Ideal for servicing and monitoring tasks with two peak-value memories and four limit value switches
  • Versions available with RS232 or RS485 device interface including software
  • Password-protected setup menu in five languages for device parameterization

Wide field of applications due to parameter memory and four limit value switches

Safe Use

  • Portable housing with carrying handle that also serves as a stand
  • Easy-to-read, 10-digit, red LED display
  • Intuitive control through robust membrane keypad with seven button elements
  • Integrated diagnostics, error, and alarm signals

Reliable use in industrial applications due to alarm signals and an easy-to-read LED display

SCOUT55 - Data Sheet Data Sheets English
SCOUT55 - Safety Instructions Safety Instructions English, French, German

Certificates and Approvals

SCOUT55 - EU Declaration of Conformity Declaration of Conformity English
Scout55
Number of inputs Single channel
Input Strain gauge full/half bridge, Inductive bridge, Resistance
Interface Analog, Digital IO, RS232
Sample rate 50 S/s
Housing Desktop
Internal logic Calculated channel
Legal for trade No