See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustic application See All Software See All Transducers See All Vibration Testing Equipment See All Electroacousticsb - OLD unpublished See All Academy See All Resource Center See All Services See All Support See All Applications See All Industries See All Our Business
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ systems See All High precision and calibration systems See All Industrial electronics See All Power Analyser See All S&V Handheld devices See All S&V Signal conditioner See All Accessories for electroacoustic application See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Temperature See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for modal exciters See All Test Solutions See All Training Courses See All Primers and Handbooks See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Acoustics See All Asset & Process Monitoring See All Electric Power See All NVH See All OEM Custom Sensors See All Structural Integrity See All Vibration See All Automotive & Ground Transportation See All Business Ethics
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories for industrial electronics See All Handheld Software See All Accessories for S&V handheld devices See All BK Connect / PULSE See All API See All Microphone sets See All Microphone Cartridges See All Acoustic calibrators See All Special microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories for strain gauges See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometer See All Charge accelerometer See All Impulse hammers / impedance heads See All Cables See All Accessories See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All Resources See All Electroacoustics See All Environmental Noise See All Noise Source Identification See All Product Noise See All Sound Power and Sound Pressure See All Vehicle Pass-by Noise See All Production Testing and Quality Assurance See All Machine Analysis and Diagnostics See All Structural Health Monitoring See All High Voltage See All OEM Sensors for the Agriculture Industry See All OEM Sensors for Robotics and Torque Applications See All Structural Dynamics See All Material Properties Testing

How can I silently install ReliaSoft desktop applications?

 

The ReliaSoft installer accepts command-line options that allow you to install the software without providing routine user inputs during installation. This is known as a silent installation. Silent installations are helpful when you have to install multiple ReliaSoft products on multiple client computers and the options you select while installing on each computer are always the same.

The ReliaSoft installer is created by the InstallShield application packaging system and will recognize the /r/s/SMS/f1, and /f2 switches. The following instructions use the ReliaSoft2022.exe installer in all examples; the same approach can be used with the ReliaSoft installers from versions 2018 through 2021 and the Synthesis installers from versions 9 through 11. You can also use this approach with the licinst.exe file to install the HBM Prenscia Licensing Administration Utility, if desired.

 

1. Create an Answer File

To perform a silent installation, you’ll need an answer file (*.iss) that will provide the inputs that would normally be provided by the user in an interactive installation session. The easiest way to create an answer file is to run an ordinary installation and record the selections you make during the installation. You can use the following command to run and record the installation:

ReliaSoft2022.exe /r /f1"C:\silent install\Setup.iss"

where:

/r (required) records the user inputs during the ordinary installation and saves them to an answer file.

/f1"C:\silent install\Setup.iss" (optional) specifies an alternate location and name for the answer file. Use an absolute path. If omitted, a Setup.iss file will be created in the "c:\Windows" directory.

 

2. Run a Silent Installation

Once an answer file is available, use the following command to perform a silent installation on a client computer:

ReliaSoft2022.exe /s /SMS /f1"C:\silent install\Setup.iss" /f2"C:\silent install\Result.log"

where:

/s (required) runs the installer using the "silent" option.

/SMS (optional) prevents a network connection and the installer from closing before the installation is complete. This is useful if you are running the installation as part of a larger script (e.g., one script that triggers multiple events in a sequence). If omitted, the system will attempt to run the next command in the sequence, regardless of whether the installation is complete.

/f1"C:\silent install\Setup.iss" (required) specifies the location and name of the answer file.

/f2"C:\silent install\Result.log" (optional) creates a log of the installation in the specified location with the specified filename.

 

Checking for Errors

If you created a log of the installation, the log file will contain a ResultCode key that returns one of the following values:

 

ResultCode Definition
0 Success
-1 General error
-2 Invalid mode
-3 The required data not found in the Setup.iss file
-4 Not enough memory available
-5 File does not exist
-6 Cannot write to the response file
-7 Unable to write to the log file
-8 Invalid path to the InstallShield Silent response file
-9 Not a valid list type (string or number)
-10 Data type is invalid
-11 Unknown error during setup
-12 Dialogs are out of order
-51 Cannot create the specified folder
-52 Cannot access the specified file or folder
-53 Invalid option selected

 

 

3. Additional Steps for Locally Hosted Licensing

These additional steps apply only if you’re using locally hosted licensing (see Locally Hosted Licensing).

 

Define the Path to the License Server

You will need to connect each client computer to the appropriate license server. To do this silently, you can simply add the following command to your install script:

setx HBMUK_LICENSE_PATH PORT@HOST

where PORT@HOST should be 6220@servername (servername can be the resolved name or IP address).

 

Import the License Settings File

 

NOTE: Beginning with Version 2020, a license settings file (*.prnrsl) will not be provided and this step will not apply. Instead, a new type of license settings file will automatically be created when a user launches their software while pointed to a license server configured for locally hosted licensing. In situations where a mix of locally hosted and ReliaSoft-hosted licenses will be used or where a suite of products has been merged with other products, the license settings file will need to be edited via the License Settings tool.

 

For versions prior to Version 2020: If a license settings file (*.prnrsl) was provided to you, you’ll need to import it to the client computer after the silent installation. This can be done manually or silently.

  •  

    To import the file manually, open the Import/Export License Settings utility on the client computer by choosing ReliaSoft [Version] > ReliaSoft [Version] License Settings Import-Export (Windows 10) or ReliaSoft [Version] > Additional Tools > ReliaSoft [Version] License Settings Import-Export (Windows 7) in the Windows Start menu. Follow the on-screen instructions to import the *.prnrsl file.

  • To import the file silently, run the following command in the directory of the ReliaSoft installation on the client computer. The default installation path is "C:\Program Files (x86)\ReliaSoft\ReliaSoft [Version]." You can run the command separately from the silent installation, or you can create a batch file with both commands in it and run the batch file.

LMXLicSettingsImportExport.exe /i"C:\path\filename.prnrsl"

 

Where:

/i"C:\path\filename.prnrsl" causes the Import/Export License Settings utility to import the license settings file from the specified path. If no path is specified, the utility will open a browse window for you to specify the path (i.e., this step will not be silent).

 

You can also use this command with different arguments:

/e"C:\path\filename.prnrsl" causes the Import/Export License Settings utility to export a copy of the license settings file to the specified location and filename.

/d deletes the license settings file from the location where the software uses it.